99 Agney Avenue, Terryville, Connecticut, USA 06786

Hot Zone:

  • 8” diameter x 8” high (20cm x 20cm)

External Dimensions:        

  • Very compact unit, approximately 43” wide x 45” deep (109cm x 114cm)
  • Height with bell fully open: 93” (236cm)
  • Height with bell fully closed: 75” (190cm)
  • Center post height: 85” high (216 cm)

Max. Temp.:        

  • 1100o C (2012o F)

Atmosphere:

  • High vacuum operation. Inert gas backfill to aid cooling.

Power Requirements:        

  • 240 volts, 3 phase, 60 hertz, 56 amps full load

Features:

  • Standard one-year warranty
  • This entire unit is a totally enclosed, packaged, and assembled that is shipped as one piece, requiring only the water, gas, and power to be connected to the appropriate locations.
  • Yokogawa UP550 digital programmable temperature controller with 30 programs and 300 segments.
  • Fully automatic operation with PLC programmer/controller with alphanumeric display to indicate furnace processing cycles
  • Molybdenum and graphite blanket hot zone.
  • Molybdenum heating elements 360o around the work.
  • Mechanical vacuum pump.
  • 4” diffusion pump.
  • High vacuum gauge to monitor chamber pressure
  • Digital high limit safety controller.
  • We provide written operating procedures, complete detailed electrical schematics, and manuals for all instrumentation and controls on the furnace.
  • This unit is leak-tested with a helium mass spectrometer, with no detectable leak in the 10-9 There is a built-in KF-25 leak test port that is capped that can be used to easily attach the furnace to a helium mass spectrometer leak detector.
  • Includes one day of test fire and training at our plant in Terryville, Connecticut, USA.

Options:

  • Yokogawa 6-channel DX100 paperless datalogging chart recorder with digital communications. Network compatible – can appear as a node on a network, making remote data gathering fast and easy. Includes built-in memory card for storage.
  • Remote diagnostics via a modem, enabling us to remotely aid in troubleshooting the furnace and guide your maintenance people directly. This should virtually eliminate the need for field service.
  • Yokogawa Light Loader to facilitate uploading and downloading programs, configuration files, and auto-tuning parameters. This device clips on the face of the Yokogawa UP550 instrument and plugs into a USB port on a PC-based laptop or desktop computer, greatly facilitating and simplifying instrument configuration, program storage, and auto-tuning. Can be used for writing programs and storing detailed configuration data.
Print Friendly, PDF & Email